{"title":"R-454B Refrigerant","description":"\u003cp\u003eR-454B is an A2L refrigerant blend of R-32 and R-1234yf. EPA lists it under the trade name Opteon XL41 as acceptable, subject to use conditions, for new residential and light commercial air conditioning and heat pump equipment. It is not a retrofit refrigerant for R-410A or R-22 systems.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSizes: 2 lb and 20 lb.\u003c\/li\u003e\n\u003cli\u003eGWP 470 in EPA's SNAP table, compared with 2,090 for R-410A.\u003c\/li\u003e\n\u003cli\u003eA2L cylinders typically use left-hand-thread valve outlets. See the \u003ca href=\"\/blogs\/blogs\/a2l-cylinder-left-hand-thread-adapters\"\u003eadapter guide\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eEPA Section 608 certification is required to buy. Free shipping to the 48 continental states.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompare with \u003ca href=\"\/products\/r32-refrigerant\"\u003eR-32\u003c\/a\u003e, or read the \u003ca href=\"\/blogs\/blogs\/r410a-to-a2l-transition-guide\"\u003eR-410A to A2L transition guide\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eSources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.epa.gov\/snap\/substitutes-residential-and-light-commercial-air-conditioning-and-heat-pumps\" rel=\"noopener\"\u003eEPA SNAP, Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.govinfo.gov\/content\/pkg\/FR-2021-05-06\/pdf\/2021-08968.pdf\" rel=\"noopener\"\u003eFederal Register, 86 FR 24444 (May 6, 2021), SNAP listing of R-454B and others\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.epa.gov\/section608\/questions-and-answers-about-refrigerant-sales-restriction\" rel=\"noopener\"\u003eEPA, Questions and Answers about the Refrigerant Sales Restriction\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"r454b","title":"R-454B Refrigerant (Opteon XL41) – 2 lb \u0026 20 lb","description":"\u003ch2\u003eR-454B refrigerant in 2 lb and 20 lb sizes\u003c\/h2\u003e\n\u003cp\u003eR-454B is an A2L refrigerant blend of R-32 and R-1234yf. EPA's SNAP table lists it under the trade name Opteon XL41. EPA lists it for new residential and light commercial air conditioning and heat pump equipment designed for R-454B. Use it only in equipment designed and labeled for it.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 lb:\u003c\/strong\u003e a small quantity for topping off or charging smaller systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20 lb:\u003c\/strong\u003e the standard cylinder size for contractors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRefrigerant Inc ships to the 48 continental states with free shipping. EPA Section 608 certification is required to buy.\u003c\/p\u003e\n\u003ch2\u003eNot a retrofit refrigerant\u003c\/h2\u003e\n\u003cp\u003eEPA listed R-454B under the Significant New Alternatives Policy (SNAP) program as acceptable, subject to use conditions, in a final rule published May 6, 2021 (86 FR 24444). The use conditions limit it to new equipment designed specifically for the refrigerant that meets UL 60335-2-40 (3rd edition) and carries the required warning labels. EPA did not list it as a conversion refrigerant for existing equipment, so do not add it to a system built for R-410A or R-22.\u003c\/p\u003e\n\u003ch2\u003eR-454B at a glance\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd\u003eR-454B, blend of R-32 and R-1234yf\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eASHRAE 34 safety class\u003c\/th\u003e\n\u003ctd\u003eA2L (lower toxicity, mildly flammable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eGlobal warming potential\u003c\/th\u003e\n\u003ctd\u003e470 (EPA SNAP table). Manufacturers often cite 466 on a different GWP basis. R-410A is listed at 2,090 in the EPA table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOzone depletion potential\u003c\/th\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eUse\u003c\/th\u003e\n\u003ctd\u003eNew equipment designed for R-454B only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSizes\u003c\/th\u003e\n\u003ctd\u003e2 lb and 20 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePurchase\u003c\/th\u003e\n\u003ctd\u003eEPA Section 608 certified technicians, or buyers who employ one\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eServicing A2L equipment\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUse recovery machines, recovery cylinders, gauges and leak detectors rated for A2L refrigerants.\u003c\/li\u003e\n\u003cli\u003eRead the equipment nameplate to confirm the refrigerant, and follow the manufacturer's service instructions and local codes.\u003c\/li\u003e\n\u003cli\u003eA2L cylinders typically use a left-hand-thread valve outlet. See our \u003ca href=\"\/blogs\/blogs\/a2l-cylinder-left-hand-thread-adapters\"\u003eguide to A2L cylinder adapters\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eDo not mix R-454B with another refrigerant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRules that apply to this purchase\u003c\/h2\u003e\n\u003cp\u003eUnder the AIM Act and EPA's Technology Transitions rule, new residential and light commercial air conditioning and heat pump systems are limited to refrigerants with a GWP of 700 or less, with manufacture and import restrictions starting January 1, 2025. R-454B is below that limit. In May 2026 EPA finalized a reconsideration rule that removed the installation compliance date for systems whose specified components were all manufactured or imported before January 1, 2025. EPA states that the rule does not restrict continued use or servicing of existing systems, so R-410A remains available for servicing existing R-410A equipment.\u003c\/p\u003e\n\u003cp\u003eRefrigerant Inc requires Section 608 certification to buy. EPA's guidance on the refrigerant sales restriction says sellers, including online sellers, must verify that the buyer is a certified technician or employs one, and must keep invoice records for three years. Read more on our \u003ca href=\"\/pages\/epa-guidelines\"\u003eEPA guidelines page\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eIs R-454B a drop-in replacement for R-410A?\u003c\/h3\u003e\n\u003cp\u003eNo. EPA lists R-454B as acceptable, subject to use conditions, for new residential and light commercial air conditioning and heat pump equipment that is designed for it. The listing does not cover converting existing R-410A systems. If your equipment runs R-410A, keep using R-410A for service.\u003c\/p\u003e\n\u003ch3\u003eIs R-454B flammable?\u003c\/h3\u003e\n\u003cp\u003eR-454B is classified A2L under ASHRAE 34, which means lower toxicity and mildly flammable. Use A2L-rated recovery and service equipment, ventilate the work area, and follow the equipment manufacturer's instructions and local codes.\u003c\/p\u003e\n\u003ch3\u003eWhat is R-454B made of?\u003c\/h3\u003e\n\u003cp\u003eR-454B is a blend of R-32 and R-1234yf (EPA's SNAP rule gives the mass split as 68.9 percent R-32 and 31.1 percent R-1234yf). EPA's SNAP table lists it under the trade name Opteon XL41.\u003c\/p\u003e\n\u003ch3\u003eDoes R-454B need a left-hand-thread adapter?\u003c\/h3\u003e\n\u003cp\u003eA2L cylinders typically use a left-hand-thread valve outlet so they are not confused with non-flammable refrigerants. Standard hoses have right-hand fittings, so technicians typically use a left-hand-to-right-hand adapter. Check the valve outlet on the cylinder you receive. Adapters are sold separately by tool makers and supply houses.\u003c\/p\u003e\n\u003ch3\u003eDo I need special tools for R-454B?\u003c\/h3\u003e\n\u003cp\u003eYour recovery machine, recovery cylinders, gauges and leak detector should be rated for A2L refrigerants. Check the tool maker's rating and the equipment manufacturer's service instructions.\u003c\/p\u003e\n\u003ch3\u003eWho can buy R-454B?\u003c\/h3\u003e\n\u003cp\u003eEPA Section 608 certified technicians, and buyers who employ one. EPA's guidance on the refrigerant sales restriction says sellers, including online sellers, must verify this and keep sales invoices for three years. Call 888-593-7366 for contractor accounts.\u003c\/p\u003e\n\u003ch3\u003eIs there a separate A2L certification from EPA?\u003c\/h3\u003e\n\u003cp\u003eEPA's Section 608 page lists Type I, Type II, Type III and Universal. It does not list an A2L-specific federal credential. Manufacturers, trade groups and local codes may still call for A2L safety training.\u003c\/p\u003e\n\u003ch2\u003eRelated\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/a2l-refrigerants\"\u003eA2L refrigerants\u003c\/a\u003e | \u003ca href=\"\/products\/r32-refrigerant\"\u003eR-32\u003c\/a\u003e | \u003ca href=\"\/blogs\/blogs\/r410a-to-a2l-transition-guide\"\u003eR-410A to A2L transition guide\u003c\/a\u003e | \u003ca href=\"\/pages\/wholesale-refrigerant-accounts\"\u003eWholesale accounts\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003eSources\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.epa.gov\/climate-hfcs-reduction\/background-hfcs-and-aim-act\" rel=\"noopener\"\u003eEPA, Background on HFCs and the AIM Act\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.epa.gov\/hfcs\/technology-transitions-hfc-restrictions-sector\" rel=\"noopener\"\u003eEPA, Technology Transitions HFC Restrictions by Sector\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2026-05\/technology-transitions-final-rule-fact-sheet-updated-may-2026.pdf\" rel=\"noopener\"\u003eEPA, Technology Transitions final rule fact sheet (maintenance of legacy systems)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2026-05\/fact-sheet-san-12166-technology-transitions-frm.pdf\" rel=\"noopener\"\u003eEPA, Fact sheet: 2026 Technology Transitions reconsideration final rule\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.epa.gov\/snap\/substitutes-residential-and-light-commercial-air-conditioning-and-heat-pumps\" rel=\"noopener\"\u003eEPA SNAP, Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.govinfo.gov\/content\/pkg\/FR-2021-05-06\/pdf\/2021-08968.pdf\" rel=\"noopener\"\u003eFederal Register, 86 FR 24444 (May 6, 2021), SNAP listing of R-454B and others\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.epa.gov\/section608\/section-608-technician-certification-requirements\" rel=\"noopener\"\u003eEPA, Section 608 Technician Certification Requirements\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.epa.gov\/section608\/questions-and-answers-about-refrigerant-sales-restriction\" rel=\"noopener\"\u003eEPA, Questions and Answers about the Refrigerant Sales Restriction\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Refrigerant Inc","offers":[{"title":"2lbs","offer_id":42394562822190,"sku":"R454B-2lb","price":186.25,"currency_code":"USD","in_stock":true},{"title":"20lbs","offer_id":41359839395886,"sku":"R454B-91","price":512.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/8249\/9630\/files\/1_e48d7367-5a74-49af-9541-7cbf0f1e136f.webp?v=1768943388"}],"url":"https:\/\/www.refrigerantinc.com\/collections\/r454b-refrigerant.oembed","provider":"Refrigerant Inc","version":"1.0","type":"link"}