Refrigerant Inc
R-454B Refrigerant (Opteon XL41) – 2 lb & 20 lb
R-454B Refrigerant (Opteon XL41) – 2 lb & 20 lb
Couldn't load pickup availability
R-454B refrigerant in 2 lb and 20 lb sizes
R-454B is an A2L refrigerant blend of R-32 and R-1234yf. EPA's SNAP table lists it under the trade name Opteon XL41. EPA lists it for new residential and light commercial air conditioning and heat pump equipment designed for R-454B. Use it only in equipment designed and labeled for it.
- 2 lb: a small quantity for topping off or charging smaller systems.
- 20 lb: the standard cylinder size for contractors.
Refrigerant Inc ships to the 48 continental states with free shipping. EPA Section 608 certification is required to buy.
Not a retrofit refrigerant
EPA listed R-454B under the Significant New Alternatives Policy (SNAP) program as acceptable, subject to use conditions, in a final rule published May 6, 2021 (86 FR 24444). The use conditions limit it to new equipment designed specifically for the refrigerant that meets UL 60335-2-40 (3rd edition) and carries the required warning labels. EPA did not list it as a conversion refrigerant for existing equipment, so do not add it to a system built for R-410A or R-22.
R-454B at a glance
| Refrigerant | R-454B, blend of R-32 and R-1234yf |
|---|---|
| ASHRAE 34 safety class | A2L (lower toxicity, mildly flammable) |
| Global warming potential | 470 (EPA SNAP table). Manufacturers often cite 466 on a different GWP basis. R-410A is listed at 2,090 in the EPA table. |
| Ozone depletion potential | 0 |
| Use | New equipment designed for R-454B only |
| Sizes | 2 lb and 20 lb |
| Purchase | EPA Section 608 certified technicians, or buyers who employ one |
Servicing A2L equipment
- Use recovery machines, recovery cylinders, gauges and leak detectors rated for A2L refrigerants.
- Read the equipment nameplate to confirm the refrigerant, and follow the manufacturer's service instructions and local codes.
- A2L cylinders typically use a left-hand-thread valve outlet. See our guide to A2L cylinder adapters.
- Do not mix R-454B with another refrigerant.
Rules that apply to this purchase
Under the AIM Act and EPA's Technology Transitions rule, new residential and light commercial air conditioning and heat pump systems are limited to refrigerants with a GWP of 700 or less, with manufacture and import restrictions starting January 1, 2025. R-454B is below that limit. In May 2026 EPA finalized a reconsideration rule that removed the installation compliance date for systems whose specified components were all manufactured or imported before January 1, 2025. EPA states that the rule does not restrict continued use or servicing of existing systems, so R-410A remains available for servicing existing R-410A equipment.
Refrigerant Inc requires Section 608 certification to buy. EPA's guidance on the refrigerant sales restriction says sellers, including online sellers, must verify that the buyer is a certified technician or employs one, and must keep invoice records for three years. Read more on our EPA guidelines page.
Frequently asked questions
Is R-454B a drop-in replacement for R-410A?
No. EPA lists R-454B as acceptable, subject to use conditions, for new residential and light commercial air conditioning and heat pump equipment that is designed for it. The listing does not cover converting existing R-410A systems. If your equipment runs R-410A, keep using R-410A for service.
Is R-454B flammable?
R-454B is classified A2L under ASHRAE 34, which means lower toxicity and mildly flammable. Use A2L-rated recovery and service equipment, ventilate the work area, and follow the equipment manufacturer's instructions and local codes.
What is R-454B made of?
R-454B is a blend of R-32 and R-1234yf (EPA's SNAP rule gives the mass split as 68.9 percent R-32 and 31.1 percent R-1234yf). EPA's SNAP table lists it under the trade name Opteon XL41.
Does R-454B need a left-hand-thread adapter?
A2L cylinders typically use a left-hand-thread valve outlet so they are not confused with non-flammable refrigerants. Standard hoses have right-hand fittings, so technicians typically use a left-hand-to-right-hand adapter. Check the valve outlet on the cylinder you receive. Adapters are sold separately by tool makers and supply houses.
Do I need special tools for R-454B?
Your recovery machine, recovery cylinders, gauges and leak detector should be rated for A2L refrigerants. Check the tool maker's rating and the equipment manufacturer's service instructions.
Who can buy R-454B?
EPA Section 608 certified technicians, and buyers who employ one. EPA's guidance on the refrigerant sales restriction says sellers, including online sellers, must verify this and keep sales invoices for three years. Call 888-593-7366 for contractor accounts.
Is there a separate A2L certification from EPA?
EPA's Section 608 page lists Type I, Type II, Type III and Universal. It does not list an A2L-specific federal credential. Manufacturers, trade groups and local codes may still call for A2L safety training.
Related
A2L refrigerants | R-32 | R-410A to A2L transition guide | Wholesale accounts
Sources
- EPA, Background on HFCs and the AIM Act
- EPA, Technology Transitions HFC Restrictions by Sector
- EPA, Technology Transitions final rule fact sheet (maintenance of legacy systems)
- EPA, Fact sheet: 2026 Technology Transitions reconsideration final rule
- EPA SNAP, Substitutes in Residential and Light Commercial Air Conditioning and Heat Pumps
- Federal Register, 86 FR 24444 (May 6, 2021), SNAP listing of R-454B and others
- EPA, Section 608 Technician Certification Requirements
- EPA, Questions and Answers about the Refrigerant Sales Restriction